Restart of Comtrol Rover Interface Controller (RIC) for Key Integrations
After a restart of the Comtrol RIC (see steps below), you will need to initiate a new key link request manually for key integrations through Comtrol. To restart the Comtrol RIC, follow these steps:
- Click on the “Start” button and find the “Services” option.
- In the “Services” window, search for “Lodging Link,” (LL) and later “Rover Interface Controller” (RIC)
- To stop each interface, click on the “STOP” button in the header bar at the top of the window, then click on the “PLAY” button to restart.
- You’ll want to follow this order when you restart the system:
- LL (STOP) → RIC (STOP) → LL (START) → RIC (START)
This is the error you will see in Comtrol LLCC log:
[858] 1 08-Jun-2022 11:40:18 '7085800013799991790011181001118400101920018193090UHLL Key Link Request sequence must be successfully completed before issuing key commands.'
When this appears, you need to log into Stayntouch PMS and navigate to Settings > Integrations > Comtrol > Settings. From here, turn OFF the ACTIVATE / INACTIVE toggle, click SAVE CHANGES, and then turn the ACTIVATE / INACTIVATE toggle back ON.